Description
Cascade multiswitch for 1 Satellite position with 5 inputs and 5 trunk outputs, suitable for distributing satellite and terrestrial signals in small to large sized systems. Available with 32 subscriber outputs and powered by the TMS PSU external power supply either directly or via the SAT trunk lines.
Dependability guaranteed: a 6-year warranty is our guarantee that TRIAX’s core values of reliability and innovation are the foundation of our new multiswitches.
The TMS 5×32 C EB offers excellent performance and flexibility, with a compact design for installations even in confined spaces.
Main features:
- Low insertion loss
- High isolation
- Low power consumption
- RED compliant
- ESD Protection
- Flexibility
- Easier to select the right product
- Fewer products to stock
- Active/Passive Terrestrial Switch
- Convenience
- Equidistant F-connectors on all multiswitches
- Colour-coded input labels
- LED power indicator
- Flexible power injection
- Earth bars
TMP 5×32 Stand alone – 4SAT+1TER+PSU / 32out – LTE protectedMains powered, stand alone multiswitchMain features
• LTE Protected
• Compact design
• 4 satellite polarities and 1 terrestrial input, combined output
• Signal level controls on all inputs
• Colour coded connections
• Switch mode power supply for optimum performance
• Supplied with input and output earth bond barsCHARACTERISTICS
Input polarity gain control TER: 15.0 dB
Input polarity gain control SAT: 4 x 10.0 dB
Max. output level SAT @ -35 dB IMD3: 100 dBµV
Max. output level TER @ 60dB IMD3: 88 dBµV
Output level control – medium cable: 6 dB
Output level control – short cable: 12 dB
LNB current max.: 1000 mA
Switch commands: 13V/18V – 13V/22 kHz – 18V/22 kHzFREQUENCY
Frequency range TER: 47-790 MHz
Frequency range SAT: 950-2150 MHzLOSS
Insertion loss – SAT: 3 dB
Equalization TER: 10.0ISOLATION
Isolation SAT to TER: 30 dB
Isolation TER to SAT: 30 dB
Isolation cross polarisation H/V: 30 dB
Isolation out-out SAT: 30 dB
Isolation out-out TER: 30 dBRETURN LOSS
Return loss SAT inputs: 10 dB
Return loss SAT outputs: 8 dB
Return loss TER inputs: 10 dB
Return loss TER outputs: 8 dBELECTRICAL
Impedance: 75 ΩOPERATIONAL
LINE power DC voltage (max.): 12.0 Switchable VDC
LINE power current (max.): 50.0 mA
AC Supply voltage: 180…264 VAC
DC Current consumption (typ.): 1500 (47-63 HZ) mA
Temperature range: 0…+55 °CCONNECTORS
Number of inputs: 5
Subscriber outputs: 32
Number of trunk inputs: 4 SAT, 1 TER
Power connector: UK PlugMECHANICAL
Height (mm): 56 mm
Depth (mm): 170 mm
Width (mm): 382mm
Reviews