Description
| Product type | Feed-through terminal block |
| Area of application | Machine building |
| Plant engineering | |
| Process industry | |
| Number of connections | 2 |
| Number of rows | 1 |
| Potentials | 1 |
| Insulation characteristics | |
| Overvoltage category | III |
| Degree of pollution | 3 |
Electrical properties
| Rated surge voltage | 8 kV |
| Maximum power dissipation for nominal condition | 1.02 W |
Connection data
| Number of connections per level | 2 |
| Nominal cross section | 4 mm² |
| 1 level | |
| Stripping length | 8 mm … 10 mm |
| Internal cylindrical gage | A4 |
| Connection in acc. with standard | IEC 60947-7-1 |
| Conductor cross section rigid | 0.08 mm² … 6 mm² |
| Cross section AWG | 28 … 10 (converted acc. to IEC) |
| Conductor cross section flexible | 0.08 mm² … 4 mm² |
| Conductor cross section, flexible [AWG] | 28 … 12 (converted acc. to IEC) |
| Conductor cross-section flexible (ferrule without plastic sleeve) | 0.14 mm² … 4 mm² |
| Flexible conductor cross section (ferrule with plastic sleeve) | 0.14 mm² … 4 mm² |
| 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve | 0.5 mm² … 1 mm² |
| Nominal current | 32 A |
| Maximum load current | 40 A (with 6 mm² conductor cross section) |
| Nominal voltage | 800 V |
| Nominal cross section | 4 mm² |
Ex data
| Rated data (ATEX/IECEx) | |
| Identification | II 2 GD Ex eb IIC Gb |
| Operating temperature range | -60 °C … 110 °C |
| Ex-certified accessories | 3030420 D-ST 4 |
| 3030721 ATP-ST 4 | |
| 1204517 SZF 1-0,6X3,5 | |
| 3022276 CLIPFIX 35-5 | |
| 3022218 CLIPFIX 35 | |
| List of bridges | Plug-in bridge / FBS 2-6 / 3030336 |
| Plug-in bridge / FBS 3-6 / 3030242 | |
| Plug-in bridge / FBS 4-6 / 3030255 | |
| Plug-in bridge / FBS 5-6 / 3030349 | |
| Plug-in bridge / FBS 10-6 / 3030271 | |
| Plug-in bridge / FBS 20-6 / 3030365 | |
| Bridge data | 28 A / 4 mm² |
| Ex temperature increase | 40 K (33.4 A / 4 mm²) |
| Rated voltage | 550 V |
| for bridging with bridge | 550 V |
| – At bridging between non-adjacent terminal blocks | 352 V |
| – At bridging between non-adjacent terminal blocks via PE terminal block | 352 V |
| – At cut-to-length bridging with cover | 220 V |
| – At cut-to-length bridging with partition plate | 275 V |
| Rated insulation voltage | 500 V |
| output | (Permanent) |
| Ex level General | |
| Rated current | 30 A |
| Maximum load current | 34.5 A |
| Contact resistance | 0.63 mΩ |
| Ex connection data General | |
| Nominal cross section | 4 mm² |
| Rated cross section AWG | 12 |
| Connection capacity rigid | 0.08 mm² … 6 mm² |
| Connection capacity AWG | 28 … 10 |
| Connection capacity flexible | 0.08 mm² … 4 mm² |
| Connection capacity AWG | 28 … 12 |
Dimensions
| Width | 6.2 mm |
| End cover width | 2.2 mm |
| Height | 56 mm |
| Depth on NS 35/7,5 | 36.5 mm |
| Depth on NS 35/15 | 44 mm |
Material specifications
| Color | red |
| Flammability rating according to UL 94 | V0 |
| Insulating material group | I |
| Insulating material | PA |
| Static insulating material application in cold | -60 °C |
| Relative insulation material temperature index (Elec., UL 746 B) | 125 °C |
Mechanical properties
| Mechanical data | |
| Open side panel | Yes |
Environmental and real-life conditions
| Oscillation/broadband noise | |
| Specification | DIN EN 50155 (VDE 0115-200):2018-05 |
| Spectrum | Service life test category 2, bogie-mounted |
| Frequency | f1 = 5 Hz to f2 = 250 Hz |
| ASD level | 6.12 (m/s²)²/Hz |
| Acceleration | 3.12g |
| Test duration per axis | 5 h |
| Test directions | X-, Y- and Z-axis |
| Result | Test passed |
| Shocks | |
| Specification | DIN EN 50155 (VDE 0115-200):2008-03 |
| Pulse shape | Half-sine |
| Acceleration | 5g |
| Shock duration | 30 ms |
| Number of shocks per direction | 3 |
| Test directions | X-, Y- and Z-axis (pos. and neg.) |
| Result | Test passed |
| Ambient conditions | |
| Ambient temperature (operation) | -60 °C … 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) |
| Ambient temperature (storage/transport) | -25 °C … 60 °C (for a short time, no longer than 24 h, -60°C to +70°C) |
| Ambient temperature (assembly) | -5 °C … 70 °C |
| Ambient temperature (actuation) | -5 °C … 70 °C () |
| Permissible humidity (operation) | 20 % … 90 % |
| Permissible humidity (storage/transport) | 30 % … 70 % |
Standards and regulations
| Connection in acc. with standard | IEC 60947-7-1 |
Mounting
| Mounting type | NS 35/7,5 |
| NS 35/15 |