080-6969-0007 +91-9729991790
(INR)

    VISION X Ray Machine (300 mA) with High frequency generator (VISION) (Vision 300)

    680,000.00

    sold by
    Yash Retail

    “Type of frequency generator High frequency generator
    Provision of Anatomical programming radiography Yes
    Maximum Exposure time in milli second upto 4
    Electromagnetic brakes with fully counter balanced mechanism for tube movement Yes
    Minimum intensity of light field lamp ?100 lux
    Type of table provided Floating table top
    Table top material with low attenuation and scratch resistant surface Carbon fiber
    System should have longitudinal and horizontal table top movements Yes
    Table should have provision for lateral imaging, without patient movement Yes
    Range of movements for the table Transverse movements of + 10cm or more & Longitudinal movements+ 40 cm with electromagnetic brakes
    Facilities of height adjustments Yes
    Anti-collision and safety devices provided No
    Provision of doing chest radiography without grid Yes
    Number of installations of the X- ray machines in Central /State/PSU Govt Hospitals (Note: Seller should furnish a performance certificate of the device to the buyer if demanded after placement of order) <3 Availability of toll free facility for technical support maintened by OEM or authorized agencies Yes Comprehensive Warranty in Years 5 Patient fixing belts and compression device (for performing excretory urography, etc) Yes Light weight ?zero lead? radiation protection aprons provided No Lateral cassette holder provided No Model No: VISION 300 Make: Vision Size: 300mA"

    • Free Shipping in India
    • |
    • 4 - 7 working days
    • |
    • International Shipping
    • |
    • 7 - 14 working days
    Share:

    Description

    “Standards
    Conformity to Certification CDSCO/AERB
    Certification number and date 99-TA-771 21/09/2017
    Type test approval from AREB required Yes
    AREB approval certificate number of Particular Model 99-TA-771
    Confirmity to manufacturing standards ISO 13485
    Conformity to safety standards IEC 60601-2-54 or BIS equivalents
    Performance Parameters
    Purpose For Radiographic examinations
    Type of frequency generator High frequency generator
    Frequency generator output in kW 24
    KVP range in KV 40 -125
    Current output 300 mA or more at 100 kV
    Provision of Anatomical programming radiography Yes
    Over loading protection Yes
    X-ray tube positioning Floor Mount Tube stand
    X ray tube should be high speed rotating anode and must have dual focus Yes
    Tube rotation in degree 120
    Size of large focal spot in mm Upto 2 mm
    Size of small focal spot in mm Upto 1 mm
    Anode Rotation Speed (minimal) per minute 2800
    Permanent Filtration 0.9 mm Al / 75 kV
    Anode heat storage capacity (min) 140 kHU or more
    Heat dissipation rate in HU/Sec 450
    Automatic exposure control device provided Yes
    Maximum Exposure time in milli second upto 4
    Digital display for KVP & mAs provided Yes
    Range of tube movements in vertical planes in cm 150
    Range of tube movements in longitudinal in cm 150
    Range of tube movements in lateral planes in cm 150
    Electromagnetic brakes with fully counter balanced mechanism for tube movement Yes
    Facility to display tube angulation Yes
    Centering devices to be provided Yes
    Maximum source to image distance (SID) in vertical position in cm 150
    Maximum source to image distance (SID) in horizontal position in cm 100
    Collimeter rotation in degree ?180
    Multileaf collimator having halogen lamp/bright light source, with auto shut off provision of the light, should be available Yes
    Minimum intensity of light field lamp ?100 lux
    Full coverage size at a 100 cm SID(collimeter size) with ? 5 percent tolerances 430 x 430
    Type of table provided Floating table top
    Table top material with low attenuation and scratch resistant surface Carbon fiber
    Table Length in mm with ? 1 percent tolerances 1800
    Table Width in mm with ? 1 percent tolerances 600
    Table Height in mm with ? 1 percent tolerances 650
    System should have longitudinal and horizontal table top movements Yes
    Table should have provision for lateral imaging, without patient movement Yes
    Range of movements for the table Transverse movements of + 10cm or more & Longitudinal movements+ 40 cm with electromagnetic brakes
    Facilities of height adjustments Yes
    Maximum Patient weight supported by table in kg 200
    Foot switches for adjusting longitudinal/side to side movements, locking, and light adjustment Yes
    Movable Grid with grid ratio 10:1 or more
    Anti-collision and safety devices provided No
    Counterbalanced, adjustable height, wall and floor mounted, vertical Bucky Yes
    SID range of radiographic application including chest radiography in mm 1000 to 1800
    Provision of doing chest radiography without grid Yes
    Power supply Three Phase AC ( 380-440 V,50/60 Hz)
    Lead lining for doors Yes
    Number of installations of the X- ray machines in Central /State/PSU Govt Hospitals (Note: Seller should furnish a performance certificate of the device to the buyer if demanded after placement of order) <3 OEM and Reseller (if supplier is re-seller) shall ensure uninterrupted availability of all spares for 10 years Yes Availability of toll free facility for technical support maintened by OEM or authorized agencies Yes User/Technical/Maintenance manuals to be supplied in English in hard and soft copy Yes Demonstration of equipment and training to be provided after completing supplies before acceptance Yes Comprehensive Warranty in Years 5 Additional Parameters Patient fixing belts and compression device (for performing excretory urography, etc) Yes Voltage stabilizer servo controlled in KVA 50 Light weight ?zero lead? radiation protection aprons provided No Lead Aprons - Full body and Skirt type 2 No each (0.5pb) Thyroid shields supplied 4 Gonad sheet Male supplied 2 Gonad sheet Female supplied 2 Wall mounted stand for radiation protection aprons supplied Yes Lead glass window Supplied Yes Footsteps for the table supplied Yes Lateral cassette holder provided No Reports The Principal Manufacturer must have direct Presence/approved service center In India Yes Copies of reports and certifications to be furnished to buyer on demand at time of supplies Yes QA, QC and other tests as per NABH shall be carried out by OEM or authorized agency of OEM Yes Copies of all calibration and test reports to be submitted at the time of Supply of Machine Yes"

    Additional information

    Weight 200 kg
    Discounts

    10%-20%

    Reviews

    There are no reviews yet.

    Be the first to review “VISION X Ray Machine (300 mA) with High frequency generator (VISION) (Vision 300)”

    We Recommend

    lenovo v14 Laptop

    33,250.00

    Sennheiser Ear phone CX 2.00i

    2,899.00